[Kopisha] I-China Online ups Room Networking Room Three Phase rack tower 1~30KVA
Incazelo
Igama Brand: Banatton
Indawo yokuzalwa: China
Uhlobo: I-UPS eku-inthanethi
Inombolo Yemodeli: BNT900-RT 1~30KVA
Bonisa: I-LED
Isigaba: Isigaba Esodwa/Ezintathu
I-Waveform: i-sine wave ehlanzekile
Isikhathi sokudlulisa: 0ms
Amandla: 1KVA -30KVA
Ukuvikela: i-short-circuit, ama-voltage angaphezu kwamandla, ukuvikelwa kokuxhumeka okuhlehlayo
I-OEM/ODM: Yebo
Ikhono Lokuhlinzeka: 10000 Ucezu/Izingcezu Ngenyanga
Ukupakisha: Iphakethe lebhokisi lebhokisi noma njengoba ucelile
Izici
Asikho isikhala sokuyekethisa uma kuziwa ekuqinisekiseni ukwethembeka nokuphepha kwemishini ye-IT ebalulekile.Yilapho izinhlelo ze-UPS ezifakwe ngamarakhi ziqala ukusebenza khona.I-UPS ene-Rack-mounted (izinto zamandla angaphazamiseki) zenzelwe ukunikeza amandla ayisipele ngesikhathi sokunqamuka kukagesi noma ukushintshashintsha, ukuqinisekisa ukusebenza okungaphazamiseki kwamaseva, amaswishi namadivayisi okugcina.
Enye yemikhiqizo ehamba phambili embonini ye-rack UPS yaziwa ngobuchwepheshe bayo beqiniso bokuguqula kabili.Lokhu kusho ukuthi amandla angenayo e-AC ahlala eguqulwa abe amandla e-DC abese ebuyela emandleni e-AC, ehlinzeka ngokukhipha okuhlanzekile, okuzinzile kwedivayisi yakho.Lokhu kuqinisekisa ukuthi amadivayisi akho athola amandla azinzile ngokunganaki ukushintshashintsha kwevoltheji yokufaka noma imvamisa.
Ngaphezu kwalokho, lolu hlelo lwe-UPS olufakwe kwi-rack lusebenzisa ubuchwepheshe bokuguqulwa okuphindwe kabili obuku-inthanethi obusezingeni eliphezulu.Lokhu kusho ukuthi ugesi ugadwa ngokuqhubekayo futhi ulungiswa ngokuzenzakalelayo ukuze kuqedwe noma yiziphi izipikili, ama-surges noma ukucwiliswa kwamandla kagesi.Lokhu kubaluleke kakhulu emhlabeni wanamuhla wedijithali, lapho ngisho nokunqamuka kukagesi isikhashana kungase kubangele ukulahleka kwedatha okumba eqolo noma ukulimala kwemishini.
Ukuze kuthuthukiswe ukusebenza kwayo, lolu hlelo lwe-UPS olufakwe kwi-rack luhlanganisa ubuchwepheshe be-DSP.I-DSP, noma ukucutshungulwa kwesignali yedijithali, ivumela ukunemba okukhulu kanye nezikhathi zokuphendula ngokushesha lapho kuqapha futhi kulungiswa ukunikezwa kwamandla.Lokhu kuqinisekisa ukuthi idivayisi yakho ihlezi ivikelekile, ngisho nasezindaweni eziyisidingo kakhulu.
Lolu hlelo lwe-UPS olufakwe kwi-rack lunamandla okukhipha angu-0.9 futhi lungakwazi ukuphatha imithwalo yemishini ehlukahlukene.Lokhu kusho ukuthi ungakwazi ukuxhuma amadivayisi amaningi ku-UPS ngaphandle kokuphazamisa ukusebenza kwayo.Kungakhathaliseki ukuthi unamaseva anamandla amakhulu noma isitoreji esiningi, le sistimu ye-UPS ekhwezwe ngama-rack ingahlangabezana nezidingo zakho.
Esinye isici esihlukanisayo salolu hlelo lwe-UPS olufakwe ngama-rack ububanzi bawo obubanzi bokufaka amandla.Yamukela ama-voltage ukusuka ku-110 kuya ku-300 VAC, iyenze ihambisane nemithombo yamandla ehlukahlukene.Lokhu kuvumelana nezimo kuqinisekisa ukuthi kungasetshenziswa ezindaweni noma ezindaweni ezahlukene ngaphandle kwesidingo semishini eyengeziwe noma ukulungiswa.
Ngaphezu kwalokho, lolu hlelo lwe-UPS olufakwe ngama-rack luhlanganisa ubuchwepheshe bokulungisa isici samandla okufakwayo okuthuthukisiwe.Isici sawo samandla ngu-0.99, okwandisa ukusebenza kahle kwamandla okufaka, ukunciphisa ukuchithwa kwamandla kanye nokulondoloza izikweletu zikagesi.Lokhu kubaluleke kakhulu kumabhizinisi abeka phambili ukusimama nokusebenza kahle kwamandla.
Ngaphezu kwezici zayo zobuchwepheshe ezithuthukisiwe, lolu hlelo lwe-UPS olufakwe ngama-rack lunikeza uhla lwemisebenzi esebenzayo.Inemodi yokuguqula imvamisa engu-50Hz/60Hz futhi ingakwazi ukuzivumelanisa namagridi wamandla ahlukene noma izindinganiso zamazwe ngamazwe.Futhi ifaka isici Esiphuthumayo Sokuvala (i-EPO) ukuze uthole ukuphepha okwengeziwe phakathi nezimo eziphuthumayo noma umsebenzi wokulungisa.
Ukuhambisana namajeneretha kungenye inzuzo yalolu hlelo lwe-rack UPS.Ingashintsha kalula phakathi kwamapayipi amakhulu namandla ejeneretha ngaphandle kokuphazamiseka, inikeze ugesi oqhubekayo phakathi nokunqamuka kukagesi okude noma lapho amandla kagesi engathembekile.Lesi sici sizuzisa kakhulu amabhizinisi asezindaweni ezivame ukucisha ugesi.
Ukuze kube lula ukuqapha nokuphatha, lolu hlelo lwe-UPS olufakwe kwi-rack luza nezinketho zokuxhumana ze-SNMP/USB/RS-232.Lezi zixhumanisi zikuvumela ukuthi uxhume i-UPS kunethiwekhi noma ikhompuyutha futhi ufinyelele ulwazi lwesikhathi sangempela mayelana namandla, isimo sebhethri, nempilo yesistimu.Lokhu kunika amandla ukuxazulula inkinga futhi kukusiza ukuthi uqonde ukusebenza kwengqalasizinda yakho ye-IT.
Ukuqinisekisa ukusebenza kahle kwebhethri nesikhathi eside sokulondoloza, le sistimu ye-UPS efakwe kwi-rack ivumela inani lamabhethri ukuthi lilungiswe.Ungenza ngendlela oyifisayo inombolo yamayunithi ngokwezidingo zakho ezithile, okukunikeza amandla okulinganisela isikhathi sokusebenza nezindleko zesistimu.
Kumabhizinisi anezidingo zokuthembeka okuphezulu, ukucushwa kwe-N+X parallel redundancy kungakhethwa.Lesi sici sivumela amayunithi amaningi e-UPS ukuthi axhunywe ngokuhambisana ukuze kuhlinzekwe ukungabi namsebenzi esimweni sokuhluleka kwe-UPS.Lokhu kuqinisekisa ukuthi amasistimu akho abalulekile ahlala evikelekile, ngisho noma kwenzeka ukwehluleka kwehadiwe.
Okokugcina, lolu hlelo lwe-UPS olufakwe kwi-rack lunikeza ukusebenza kokuqala okubandayo.Lokhu kusho ukuthi inganikwa amandla ngaphandle kwanoma imaphi amandla amapayipi, kuncike kuphela kubhethri layo langaphakathi.Lokhu kuwusizo ikakhulukazi phakathi nokufakwa kokuqala noma uma kwenzeka ugesi ucisha ngokuphelele, okukuvumela ukuthi ubuyise isistimu yakho ngokushesha nangokuphephile ku-inthanethi.
Kafushane, uma kuziwa ekuvikeleni ingqalasizinda yakho ye-IT ebalulekile, isistimu ye-rack ye-UPS enezici ezithuthukile namandla iyadingeka.Ngobuchwepheshe bayo beqiniso bokuguqulwa okuphindwe kabili, ubuchwepheshe be-inthanethi bokuguqulwa okuphindwe kabili kwe-inthanethi kanye nobuchwepheshe be-DSP, lolu hlelo lwe-UPS olufakwe kwi-rack lunikeza ukuthembeka okuphezulu, ukusebenza kahle nokusebenza.Ububanzi bayo be-voltage yokufaka ebanzi, ukulungiswa kwesici samandla okokufaka okusebenzayo, kanye nokuhambisana namajeneretha kuyinikeza ukuguquguquka kokuzivumelanisa nezimo ezihlukene zamandla.Ukwengeza, izici ezingokoqobo ezifana nokuxhumana kwe-SNMP/USB/RS-232, ukubala kwebhethri okulungisekayo, kanye nokuzikhethela kwe-N+X parallel redundancy kuqinisekisa ukuphathwa kalula nokukaleka.Ngesici sayo sokuqala esibandayo, ungaqiniseka ukuthi isistimu yakho izohlala isebenza, noma ngabe isimo sinjani.Ngakho-ke ungayekethisi ekuvikeleni okokusebenza kwakho okubalulekile - tshala kusistimu ye-UPS efakwe i-rack eletha ukusebenza okungenakuqhathaniswa nokuthula kwengqondo.
Isibonisi somkhiqizo
1. Izinsizakalo ze-OEM&ODM ziyamukeleka.
2. I-ejenti eminingi ebanjiswene ngokuthunyelwa ngolwandle noma ngomoya.
3. Iwaranti yeminyaka engu-1, uma kuyinkinga yekhwalithi, sizohlinzeka ngezingxenye mahhala.
Izinhlelo zokusebenza
Isikhungo sokucubungula idatha, Isistimu yokusingatha, amaseva eKhompyutha, Ezokwelapha, Ithrafikhi, Ugesi, i-IT, Izimboni nezinye izimboni.
I-Factory Production Line
Ukupakisha
INDLELA | I-BNT9010S(H)-R-31 | I-BNT9015S(H)-R-31 | I-BNT9020S(H)-R-31 | |
ISIGABA | 3-isigaba phakathi / 1-isigaba ukuphuma | |||
AMAKHONO | 10000 VA/9000 W | 15000 VA/13500 W | 20000 VA / 18000 W | |
INPUT | ||||
Amandla kagesi okuzisholo | 3 x 400 VAC (3Ph+N) | |||
I-Voltage Range | I-190-520 VAC (isigaba se-3) kumthwalo we-50%;305-478 VAC (3-isigaba) ekulayisheni okungu-100%. | |||
I-Frequency Range | 46~54 Hz noma 56~64Hz | |||
Isici samandla | ≥ 0.99 @ 100% Layisha | |||
I-THDi | < 6% @ 100% Layisha | |||
OKUPHUMAYO | ||||
I-Voltage ephumayo | 208/220/230/240VAC | |||
I-AC Voltage Regulation (Imodi ye-Batt.) | ± 1% | |||
I-Frequency Range (Ibanga Elivumelanisiwe) | 46~54Hz noma 56~64Hz | |||
I-Frequency Range (Imodi ye-Batt.) | 50 Hz ± 0.1 Hz noma 60 Hz ± 0.1 Hz | |||
Isilinganiso samanje se-Crest | 3:01 | |||
Ukuhlanekezelwa kwe-Harmonic | ≤ 2% THD (Umthwalo Owumugqa);≤ 5 % THD (Umthwalo ongewona womugqa) | |||
Dlulisa | Imodi ye-AC ukuya ku-Bat.Imodi | Uziro | ||
Isikhathi | Inverter ukuze Bypass | Uziro | ||
I-Waveform (Imodi ye-Batt.) | I-Sinewave ehlanzekile | |||
UKUSEBENZA | ||||
Imodi ye-AC | 90.50% | 91% | ||
Imodi ye-ECO | 96% | 96% | ||
Imodi yebhethri | 87% | 88% | ||
IBHETHI | ||||
Uhlobo Lwebhethri | 12 V / 9 Ah | |||
Imodeli Ejwayelekile | Izinombolo | 20 (18 – 20 ama-pcs* angalungiseka) | 20 pcs x 2 strings (18 – 20 pcs* adjustable) | |
Isikhathi sokushajwa kabusha esijwayelekile | Amahora angu-9 alulama kumthamo ongu-90%. | |||
Ukushaja Kwamanje (ubukhulu.) | 1A | 2A | ||
I-Voltage yokushaja | 273 VDC ± 1% (kusekelwe ezinombolweni zebhethri ku-20 pcs) | |||
Imodeli Yesikhathi eside | Uhlobo Lwebhethri | Kuye ngomthamo wamabhethri angaphandle | ||
Izinombolo | ||||
Ukushaja Kwamanje (ubukhulu.) | 4A | |||
I-Voltage yokushaja | 273 VDC ± 1% (kusekelwe ezinombolweni zebhethri ku-20 pcs) | |||
IZIKHOMBISI | ||||
Isibonisi se-LCD | Isimo se-UPS, Izinga Lokulayisha, Izinga Lebhethri, I-voltage Yokufaka/Okukhiphayo, Isibali-sikhathi Sokukhipha, nezimo zephutha | |||
I-ALARM | ||||
Imodi yebhethri | Ikhala njalo ngemizuzwana emi-4 | |||
Ibhethri Eliphansi | Ikhala njalo ngomzuzwana | |||
Ukulayisha ngokweqile | Ikhala kabili njalo ngomzuzwana | |||
Iphutha | Ilokhu izwakala | |||
EMZIMBENI | ||||
Imodeli Ejwayelekile | Ubukhulu, D x W x H (mm) | Iyunithi ye-UPS: 668 x 438 x 133 [3U] | Iyunithi ye-UPS: 668 x 438 x 266 [6U] | |
Iphakethe lebhethri: 580 x 438 x 133 [3U] | Iphakethe lebhethri: 580 x 438 x 133 [3U] x 2PCS | |||
Isisindo Esiphelele (kg) | Iyunithi ye-UPS: 22 | Iyunithi ye-UPS: 45 | ||
Iphakethe lebhethri: 63 | Iphakethe lebhethri: 63 x 2 ama-pcs | |||
Imodeli Yesikhathi eside | Ubukhulu, D x W x H (mm) | 668 x 438 x 133 [3U] | 668 x 438 x 266 [6U] | |
Isisindo Esiphelele (kg) | 22 | 45 | ||
EZIMO | ||||
Umswakama Osebenzayo | 0-95 % RH @ 0- 40°C (Ayiminyanisi) | |||
Izinga Lomsindo | Ngaphansi kuka-60dB @ 1 mitha | Ngaphansi kuka-65dB @ 1 Meter | ||
UKUPHATHA | ||||
I-Smart RS-232 / i-USB | Isekela i-Windows2 2000/2003/XP/Vista/2008, Windows2 7/8/10, Linux kanye ne-MAC | |||
I-SNMP yokuzikhethela | Ukuphathwa kwamandla kusuka kumphathi we-SNMP nesiphequluli sewebhu |